NORER MEDICAL & TianJin Fengyi Medical Instrument Co.,Ltd.

Dental Adjustable Torque Ratchet

reviews
100items available
Inquire Now

Product Name: Dental Adjustable Torque Ratchet

Trinquete de torsión ajustable dental

------------------------------------------------------------------------------------------------

Material: Medical Stainless Steel

Size: Customized
Head Type:  Square ,Hex 
Package: Pouch
Use: This wrench was designed for use in dental applications. It should only be used by qualified personnel. It is used to screw in dental implants and to extract them at pre-adjusted torque levels

Dental Adjustable Torque Ratchet  dental torque wrench,dental implant,dental ratchet wrench

Instructions

Setting the dental implant torque wrench: The desired amount of torque can be set with the adjustment nut (1).
A scale (2)in the front of the wrench indicates the amount of torque that can be applied at that setting. 5 Ncm increments are clearly marked on the sides of the scale (from 10 to 45 Ncm).
Blocking the Torque: Setting the torque to its maximum effectively disables the torque feature.

Do not screw too tightly.

Storage: Store in a relaxed position, not exceeding 20 Ncm.

Operation

Force should only be applied at the head of the adjustment nut (1)

When reaching the desired torque, the wrench bends around the pivot (3) in the ratchet head and gives off an audible click. At this point stop pressing on the wrench €“ otherwise it will be damaged.

The wrench will return to its normal orientation when you stop applying force.

Maintenance
The wrenches are not sterilized prior to shipping.

They must be cleaned, disinfected and sterilized before use.
When cleaning, do not use abrasive detergents and do not apply excessive pressure.

To avoid damage do not clean with wire brush or metal pads.
Use only cleaning and disinfectant solutions with a ph between 5 and 10.

Please follow the cleaning / disinfectant manufacturer's instructions
Frequent but careful cleaning has little effect on the life of the ratchet.
Product life is determined by wear.
Recalibrate the wrench once a year. The wrench must be cleaned and sterilized after service.

Decontamination

If contamination is suspect at any time, disassemble the wrench and clean all the parts thoroughly.

Implant dental torque wrench

Clean the parts with cold water and a soft disinfection brush until no residue is visible.

Manual Cleaning and Disinfection